Client: What does it mean during calibration when it shows "out of range"?
Technical advisor: Hello
This often means that the value provided by the probe before calibration is too high/low to allow for calibration
https://ph-redox-pool.com/gb/content/16-ma-sonde-ph-est-elle-hors-service-
Client: That worked
Technical advisor: Hello
What values did you read?
Client: In the test, it was 11.4 without vinegar and 10.2 with vinegar
Technical advisor: For this reason, the pH value in the water is much too high (11.4), normally (6.5-7.5) and with vinegar (3-5).
Looking at the values, I think the probe has a problem. I will try it tomorrow and leave the probe in the water tonight
Client: Ok, I'll try that. Could it be the reason why the water remains cloudy?
Technical advisor: It's possible
Client: I'll get back to you tomorrow 🙂
Thank you very much!
Technical advisor: You're welcome
Client: Currently, I have a pH value of 1.9! Unfortunately, about 5 liters of pH minus were pumped into the pool before installing your new pH probe. I have already added about 2.5 kg of sodium carbonate to the pool without the value changing. What can I do?
Technical advisor: Hello
Please test the probe in this way, it could be a faulty probe https://ph-redox-pool.com/gb/content/16-ma-sonde-ph-est-elle-hors-service-