Client :
Which probe should I change on an electromagnetic pH regulator "FPH"? The device always pumps with a reading always at 100%, I think it's the probe? Thank you for your response.
Technical Advisor :
Hello, Yes it might be the probe! Are you reading the pH value on your device?
Client :
Yes, it is at the maximum setting.
Technical Advisor :
Are you in pH minus?
Client :
Yes.
Technical Advisor :
Put the probe in water with vinegar. If the probe works, then the pump should stop. Can you take a picture of your probe and your regulator? I will check the probe you need.
Client :
Okay, I will do the test. If it's the probe, what reference is needed for this model that is a few years old?
Technical Advisor :
Okay, I know. Here is the probe you need:
https://ph-redox-pool.com/gb/emec/1705-pH-Probe--for-WDPHXX.html
Client :
Okay, thank you, I will check that. Have a nice day.
Technical Advisor :
Have a nice day.