Research and advice on the use of an ORP probe for Davey Redox MC12ORP: Conversation between customer and technical advisor.

Client:
Hello, I'm looking for an ORP probe for Davey Redox MC12ORP. Thank you for your response.

Technical Advisor:
Hello. Can you send me a photo of your probe, no need to disassemble, I will check.

Client:
ORP part#5002 wt from Monarchpoolsystem.

Technical Advisor:
One moment, please...

Client:
link to image of probe 1

Technical Advisor:
Ok, one moment while we check.

Client:
link to image of probe 2

Client:
link to image of probe 3

Technical Advisor:
This one would be suitable: link to the recommended probe.

Client:
Please let me know if I should winterize it and put it in a solution.

Technical Advisor:
We use this solution below, but it comes with this solution: link to the solution.

Client:
Okay, thanks. So during winter, I leave the probe in your solution?

Technical Advisor:
Yes, that's correct.

Client:
Great, thank you for your response despite the weekend 😉.

Technical Advisor:
Make sure to keep the bottle that comes with the probe. Have a nice weekend.

Client:
Thank you.