...,.Would it be possible to have the PH-1-3-0274 and ORP-1-3-0355 probes with a

Your questions about pH and Redox probes for swimming pools

ph-redox-pool.com

avatar

avatar
bot: Question FR Mar 10, 2023, 11:36 am

. If you have any questions, please let us know.

avatar
Tue 10, 2023, 11:40 am

Good morning,
Would it be possible to have the PH-1-3-0274 and ORP-1-3-0355 probes with a direct connection? How to specify it when ordering?
Cordially

avatar
Olivier Michaud Tue 10, 2023, 11:54 am

Hello

avatar
Olivier Michaud Tue 10, 2023, 12:01 pm

We can make a direct connection like this

avatar
Olivier Michaud Tue 10, 2023, 12:01 pm

Is that what you want?

What cable length do you want? (5 m maximum)

avatar
Tue 10, 2023, 12:13 pm

3m length.
What deadlines?

avatar
Tue 10, 2023, 12:13 pm

Yes that's what I want

avatar
Olivier Michaud Tue 10, 2023, 12:15 pm

Now we can ship Monday so next Thursday to you.

avatar
Tue 10, 2023, 12:21 pm

How to specify it when ordering?

avatar
Olivier Michaud Tue 10, 2023, 12:22 pm

No worries, I see your name, and I'm going to do it.

avatar
Tue 10, 2023, 12:22 pm

Great ! THANKS

avatar
Olivier Michaud Tue 10, 2023, 12:23 pm

On the other hand, you need to place order.thank you

avatar
Olivier Michaud Tue 10, 2023, 12:27 pm

Can you also photograph me, your probes? No need to take them apart.

avatar
Tue 10, 2023, 2:50 pm

Hello, I just ordered.
In fact I make a ph and chlorine regulation system based on a Bayrol probe holder mounted on the Analytic3 and PoolManager systems. That's why I chose probes going on the analytic3. On the other hand, as my ph-Orp controller does not have a BNC socket but dry contacts, I preferred to have a direct connection at the probe output.
Cordially
Jean Pierre Marco

⁣Download BlueMail for Android ​

avatar
Olivier Michaud Tue 10, 2023, 2:51 pm

No worries, I'll do that to you.