I would like to know if the Gen pH and pH perfect probes from zodiac are com

Your questions about pH and Redox probes for swimming pools

ph-redox-pool.com

avatar

avatar
bot: Question FR Oct 16, 2022, 5:32 pm

. If you have any questions, please let us know.

avatar
Oct 16, 2022, 5:35 pm

Good morning,
I would have liked to know if the Gen pH and pH Perfect probes from Zodiac are compatible.

avatar
Olivier Michaud Oct 16, 2022, 5:37 pm

Hello, can you photograph your current probe, I will check

avatar
Olivier Michaud Oct 16, 2022, 5:37 pm

No need to disassemble it

avatar
Olivier Michaud Oct 16, 2022, 5:38 pm

Do you have a gen ph system?

avatar
Oct 16, 2022, 5:40 pm

It's a perfect zodiac pH probe that I bought from you but I think it's the central unit that's broken because the problem is still the same. So I intend to replace the central unit with a new Gen pH.

avatar
Oct 16, 2022, 5:41 pm

No, I have a perfect pH and would like to replace it with a gen pH but without changing the probe holder.

avatar
Olivier Michaud Oct 16, 2022, 5:41 pm

Why do you think it's the CPU? I think this should work

avatar
Oct 16, 2022, 5:43 pm

Because the pH indication goes from 6.5 to 6.8 to 7.5 to ... in 1 or 2 minutes. And I have the same problem with an old (3 years old) probe and the new one.

avatar
Oct 16, 2022, 5:44 pm

I calibrated them. On the 2, I sometimes have ph4 err probe

Olivier Michaud Oct 16, 2022, 5:46 pm

Dip the probe in ph4. look at the value displayed (normally around 4). and then come back after a few hours and tell me what happens

avatar
Oct 16, 2022, 5:47 pm

OK thanks. I do that.

avatar
Olivier Michaud Oct 16, 2022, 5:48 pm

See you soon then

avatar
Oct 16, 2022, 5:49 pm

What time are you available until?

avatar
Olivier Michaud Oct 16, 2022, 5:49 pm

8 a.m. or tomorrow

avatar
Oct 16, 2022, 5:50 pm

The problem is that sometimes it tells me probe ok and sometimes probe err. And only on pH 4.

avatar
Oct 16, 2022, 5:50 pm

And these variations in value, where will it come from, then?

avatar
Olivier Michaud Oct 16, 2022, 5:51 pm

precisely, it makes me think of a faulty probe, what happens. try the test, we will see if at ph4 the value is stable over time

avatar
Oct 16, 2022, 6:07 pm

It begins badly. The probe indicates 6.5 when immersed in the pH4 solution

avatar
Olivier Michaud Oct 16, 2022, 6:08 pm

Yes, it is not good. Give me your name, I'll replace the probe

avatar
Oct 16, 2022, 6:58 pm
avatar
Oct 16, 2022, 6:59 pm

Pardon. I was busy on the phone.
My name is Patrick De Blezer. 5 Cornice of the sun St Mandrier

avatar
Olivier Michaud Oct 16, 2022, 7:00 pm

Alright, I'll find your order. We'll try.

avatar
Oct 16, 2022, 7:15 pm

Here is the reference: GFGLYOTNS

avatar
Olivier Michaud Oct 16, 2022, 7:16 pm

Thank you, we ship it to you tomorrow

avatar
Oct 17, 2022, 10:56 am

Thank you so much.
Can you send me the tracking number, please?
Many thanks in advance and have a great day.

avatar
Olivier Michaud Oct 17, 2022, 10:57 am

Hello, I will have this number tomorrow.

avatar
Oct 17, 2022, 12:57 pm

Great. Thank you so much.

avatar
Oct 20, 2022, 1:01 pm

Good morning,
Probe well received. THANKS.
Calibrated and installed, we will see after a few days of filtration. On the other hand, impossible to recalibrate the previous probe: probe error on pH4.
Good day.
patrick

avatar
Olivier Michaud Oct 20, 2022, 1:02 pm

Super.have a nice day