![]() | Jul 10, 2022, 4:05 pm Are the sobndes orp universal or specific to the model of the electrolyser? |
![]() | Olivier Michaud Jul 10, 2022, 4:12 pm They are not universal. What regulator do you have (make/model)? |
![]() | Jul 10, 2022, 4:13 pm My CCEI Limpido Z3 regulator |
![]() | Olivier Michaud Jul 10, 2022, 4:13 pm One moment please |
![]() | Jul 10, 2022, 4:14 pm On the other hand, with regard to Ph probes, I believe that they are universal. |
![]() | Olivier Michaud Jul 10, 2022, 4:14 pm ORP is the English word for RedOx: https://ph-redox-pool.com/gb/ccei/1769-ORP-Probe--for-Limpido-redox.html |
![]() | Olivier Michaud Jul 10, 2022, 4:15 pm |
![]() | Jul 10, 2022, 4:19 pm between the two references that you told me, one at 90€ the other at 75€ what is the difference, is there one of better quality? |
![]() | Olivier Michaud Jul 10, 2022, 4:19 pm The first is an ORP (redox) probe, the second is the pH probe for limpido |
![]() | Jul 10, 2022, 4:22 pm Ok, I thought that the pH probes were universal and that it was enough that the connector is in conformity with that of the regulator? |
![]() | Olivier Michaud Jul 10, 2022, 4:23 pm Not necessarily ! |
![]() | Jul 10, 2022, 4:25 pm Because I have already replaced my pH probe ... without taking into account my electrolyser model ... on the advice of my swimming pool specialist ... is this a problem? |
![]() | Olivier Michaud Jul 10, 2022, 4:26 pm No, if it works, it's good |
![]() | Jul 10, 2022, 4:29 pm In addition, on the user manual for my Limpido Z3, it was indicated that for a passive wintering of several months it was better to keep the probes dry (less ageing) then rehydrate them between 12 and 24 hours after restarting. ..or on your site you say that it is imperative to keep them moist? |
![]() | Olivier Michaud Jul 10, 2022, 4:31 pm I made the probes for a very long time and in our opinion they should be kept in a humid environment (preferably in a preservation solution). This is how we sell them. |
![]() | Jul 10, 2022, 4:34 pm Well then for my next wintering I would do so in a KCL liquid solution if I understood correctly ... even if it is less practical because they must be stored vertically and above all be sure that the liquid does not evaporate. ... what happened to me the first time |
![]() | Olivier Michaud Jul 10, 2022, 4:36 pm For this we have this article: https://ph-redox-pool.com/gb/pool-buffer-calibration-solution/1646-ph-redox-wintering-kit.html |
![]() | Jul 10, 2022, 4:41 pm Thank you for your answers |
![]() | Olivier Michaud Jul 10, 2022, 4:41 pm You are welcome, do not hesitate to contact us! Have a good day |
![]() | Jul 10, 2022, 4:43 pm Thanks, have a good day |
|