Your questions about pH and Redox probes for swimming pools ph-redox-pool.com |
|
 | bot: Question FR Oct 16, 2022, 5:32 pm . If you have any questions, please let us know. |
 | Oct 16, 2022, 5:35 pm Good morning, I would have liked to know if the Gen pH and pH Perfect probes from Zodiac are compatible. |
 | Olivier Michaud Oct 16, 2022, 5:37 pm Hello, can you photograph your current probe, I will check |
 | Olivier Michaud Oct 16, 2022, 5:37 pm No need to disassemble it |
 | Olivier Michaud Oct 16, 2022, 5:38 pm Do you have a gen ph system? |
 | Oct 16, 2022, 5:40 pm It's a perfect zodiac pH probe that I bought from you but I think it's the central unit that's broken because the problem is still the same. So I intend to replace the central unit with a new Gen pH. |
 | Oct 16, 2022, 5:41 pm No, I have a perfect pH and would like to replace it with a gen pH but without changing the probe holder. |
 | Olivier Michaud Oct 16, 2022, 5:41 pm Why do you think it's the CPU? I think this should work |
 | Oct 16, 2022, 5:43 pm Because the pH indication goes from 6.5 to 6.8 to 7.5 to ... in 1 or 2 minutes. And I have the same problem with an old (3 years old) probe and the new one. |
 | Oct 16, 2022, 5:44 pm I calibrated them. On the 2, I sometimes have ph4 err probe |
| Olivier Michaud Oct 16, 2022, 5:46 pm Dip the probe in ph4. look at the value displayed (normally around 4). and then come back after a few hours and tell me what happens |
 | Oct 16, 2022, 5:47 pm |
 | Olivier Michaud Oct 16, 2022, 5:48 pm |
 | Oct 16, 2022, 5:49 pm What time are you available until? |
 | Olivier Michaud Oct 16, 2022, 5:49 pm |
 | Oct 16, 2022, 5:50 pm The problem is that sometimes it tells me probe ok and sometimes probe err. And only on pH 4. |
 | Oct 16, 2022, 5:50 pm And these variations in value, where will it come from, then? |
 | Olivier Michaud Oct 16, 2022, 5:51 pm precisely, it makes me think of a faulty probe, what happens. try the test, we will see if at ph4 the value is stable over time |
 | Oct 16, 2022, 6:07 pm It begins badly. The probe indicates 6.5 when immersed in the pH4 solution |
 | Olivier Michaud Oct 16, 2022, 6:08 pm Yes, it is not good. Give me your name, I'll replace the probe |
 | Oct 16, 2022, 6:58 pm |
 | Oct 16, 2022, 6:59 pm Pardon. I was busy on the phone. My name is Patrick De Blezer. 5 Cornice of the sun St Mandrier |
 | Olivier Michaud Oct 16, 2022, 7:00 pm Alright, I'll find your order. We'll try. |
 | Oct 16, 2022, 7:15 pm Here is the reference: GFGLYOTNS |
 | Olivier Michaud Oct 16, 2022, 7:16 pm Thank you, we ship it to you tomorrow |
 | Oct 17, 2022, 10:56 am Thank you so much. Can you send me the tracking number, please? Many thanks in advance and have a great day. |
 | Olivier Michaud Oct 17, 2022, 10:57 am Hello, I will have this number tomorrow. |
 | Oct 17, 2022, 12:57 pm Great. Thank you so much. |
 | Oct 20, 2022, 1:01 pm Good morning, Probe well received. THANKS. Calibrated and installed, we will see after a few days of filtration. On the other hand, impossible to recalibrate the previous probe: probe error on pH4. Good day. patrick |
 | Olivier Michaud Oct 20, 2022, 1:02 pm |
|
|
| |
|