Client:
Hello, we have an Avady redox regulator and the documentation states not to exceed 15mg/l of stabilizer. We changed the probes because they were defective and ordered them on your website (pH and redox). Should this instruction still be followed or is it possible to increase the stabilizer level? The consumption of liquid chlorine is quite high due to the low stabilizer level.
Technical Advisor:
What redox value are you reading?
Client:
It depends on the periods (we had done a shock treatment with active oxygen). Normally, we are between 680 and 700.
Technical Advisor:
If you have done this treatment, you need to wait a few days for it to balance out.
Client:
We did it several weeks ago, the values before and after balance out between 680 and 700 on average. I did not take into account the values during the period with the oxygen shock.
Technical Advisor:
So you have a redox value of 680?
Client:
Yes.
Technical Advisor:
If you put the probe in the standard solution, what value do you read?
Client:
We did it last week and we had a difference of 15mv.
Technical Advisor:
15 mv compared to the value of the standard?
Client:
Yes, we had 490 instead of 475.
Technical Advisor:
What redox setpoint value do you have?
Client:
We have a setpoint between 680 and 700 depending on the water temperature.