Solving pH and REDOX Probes Calibration and Circulation Issues in Astral Pools

Client:
Hello, I want to calibrate my pH and REDOX probes but I don't have the closure plug when I place the probe. Regards, Pierre Gentil.

Yes, but you need to turn it back on for calibration in the product!

Maybe.

Okay, thanks for the info!!!

Another problem, the products, chlorine and pH, are not circulating, even though the devices are running??

Yes, Astral pool.

Yes, and I have replaced the small rubber tubes.

Yes, no flow in the circuit.

My 2 20l containers are full and positioned higher than the pumps, it should even flow by siphoning effect!!??

Okay, thank you, I will contact you later. Have a good day. Ps: I'm looking for a pool technician in Herault, is that your area?

Technical Advisor:
Hello, can you turn off the pump during calibration?

Ouch! Do you have old probes?

Okay, in that case, place the old ones instead of the new ones during calibration.



Do you have peristaltic pumps?

Are the rollers turning?

Both have an issue?

Either there is a hole in the circuit, or there is no liquid to aspirate, or the rubber tube is not properly positioned and therefore not sufficiently crushed to aspirate.

It's not easy to see remotely. Check if the rubber tube is crushed!

Oh no!